GC ELECTRONICS -- LIQUID TAPE, 10-1762 -- 8040-00N021994
===================== Product Identification =====================
Product ID:LIQUID TAPE, 10-1762
MSDS Date:03/07/1989
FSC:8040
NIIN:00N021994
=== Responsible Party ===
Company Name:GC ELECTRONICS
Address:1801 MORGAN ST
City:ROCKFORD
State:IL
ZIP:61105-1209
Country:US
Info Phone Num:815-968-9661
Emergency Phone Num:815-968-9661
Preparer's Name:VERE HAGEMAN
CAGE:72653
=== Contractor Identification ===
Company Name:GC THORSEN
Address:1801 MORGAN STREET
Box:City:ROCKFORD
State:IL
ZIP:61105
Country:US
Phone:815-968-9661
CAGE:72653
============= Composition/Information on Ingredients =============
Ingred Name:NO INGREDIENT FOR THIS FORMULATION_INGREDIENT
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS MAY
CAUSE MILD DEPRESSION, CONVULSIONS, LOSS OF CONSCIOUSNESS,
DERMATITIS. EYE IRRITATION MAY RESULT FROM CONTACT.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH WATER FOR AT LEAST 15 MINUTES. GET MD.
SKIN:WASH WITH SOAP & WATER. INHAL:FRESH AIR, OXYGEN, ARTIFICIAL
RESPIRATION. CALL MD. INGEST:DO NOT INDUCE VOMITING. CALL MD.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:45.0F,7.2C
Lower Limits:1.2%
Upper Limits:9%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER SPRAY OR FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . VENTILATE AREA WELL. TOXIC FUMES MAY RESULT
FROM COMBUSTION.
Unusual Fire/Explosion Hazard:EMPTY CONTAINERS MAY CONTAIN EXPLOSIVE
VAPORS.
================== Accidental Release Measures ==================
Spill Release Procedures:PICK UP WITH INERT ABSORBENT. STORE IN SEALED
CONTAINERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:COOL, DRY AREA, AWAY FROM IGNITION
SOURCES.
Other Precautions:USE WITH ADEQUATE VENTILATION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED CARTRIDGE RESPIRATOR OR
SCBA.
Ventilation:LOCAL AND MECHANICAL EXHAUST AS NECESSARY TO MEET TLV'S.
Protective Gloves:RUBBER OR PLASTIC GLOVES AS NECESSARY.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
HCC:F3
Boiling Pt:B.P. Text:>168F,76C
Vapor Pres:38
Vapor Density:3.9
Spec Gravity:0.930
Evaporation Rate & Reference:1.7 (BUTYL ACETATE=1)
Solubility in Water:20%
Appearance and Odor:BLACK LIQUID ALCOHOL ODOR
Percent Volatiles by Volume:70
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:HGH TEMPERATURES OR OPEN FLAMES.
Hazardous Decomposition Products:CO, CO2.
==================== Disposal Considerations ====================
Waste Disposal Methods:LICENSED INCINERATOR OR PER LOCAL, STATE AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.